Steam Traps,
Trap Monitoring |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Membrane
Steam Trap |
|
Model # |
Thermostatic steam trap with
membrane regulator. Corrosion-resistant thermostatic capsule
unaffected by waterhammer. Integral Y-type strainer and non-return
valve. Asbestos-free cover gasket (graphite/CrNi). Installation
in any position. the traps with standard capsule N discharge the
condensate with virtually no banking-up, the traps with special
capsule U with an subcooling of approx. 30K. MK45-1 with tandem
seat, MK 45-2 with single seat.
Thermostatic steam trap with membrane
regulator for use in saturated applications. Available in 1/2", 3/4"
and 1" sizes, and capacity requirements up to 1,500 lb/hr with maximum
service pressure of 465 psig. |
|
|
Features and Benefits |
|
|
- Very low subcooling
- Perfect air venting
- Quick response
- Pressure ratings up to PN 40
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bimetallic
Steam Trap |
|
Model
# |
Thermostatic/thermodynamic steam
traps with corrosion-resistant regulator unaffected by waterhammer.
Integral strainer and non-return valve action. Automatic deaeration.
Installation in any position. |
|
|
Features and Benefits |
|
|
- Waterhammer resistant
- Corrosion resistant
- Easy maintenance and repair
- Integrated non-return valve
- Integrated strainer for optimized regulator protection
- Asbestos-free cover gasket (graphite/CrNi)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bimetallic Steam Trap |
|
Model
# |
Thermostatic
stem trap with corrosion-resistant thermostatic element (Duo stainless
steel bimetallic regulator) unaffected by waterhammer.
Y-type strainer, non-return valve and asbestos-free cover gasket
(graphite) included as standard. the traps with standard regulator
discharge the condensate with virtually no banking-up. Optionally
BK45U with an under cooling of approx. 30 K (to utilize the condensate
heat in steam tracers).
Field application: Draining of saturated steam and superheated steam
lines and steam tracers. Can also be used for air-venting. Installation
in any position. In horizontal pipes the cover must be on top.
|
|
|
Features
and Benefits |
|
|
- Waterhammer-resistant
- Corrosion resistant
- Easy maintenance and repair
- Integrated non-return valve
- Y-strainer for easy access
- High efficiency
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ball
Float Steam Trap |
|
Model
# |
Ball Float Steam
Traps with rolling ball valve and Duplex control (thermostatic bellows
for automatic air-venting) for draining large condensate flow rates
from steam systems. With Simplex control (without bellows) and hand-vent
valve for the discharge of cold condensate or distillates and for
draining superheated steam, gas or compressed-air lines.
UNA23h for horizontal lines and
UNA23v for vertical lines. |
|
- UNA23
- UNA23h
- UNA23v
- UNA25
- UNA26
- UNA26h
- UNA27h
|
Features
and Benefits |
|
|
- Discharge of condensate without
subcooling
- Automatic air venting when system
is cold
- Operation in systems with variable
pressures
- Long service time
- Unaffected by dirt
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ball
Float Steam Trap |
|
Model
# |
Ball Float Steam
Traps with rolling ball valve. The steam traps can be used for all
operating conditions, as they are unaffected by back pressure. They
consist of a body with bolted cover and a control unit. the control
unit is freely accessible after removing the cover. It can be completely
replaced without having to remove the valve body from the line. |
|
|
Features
and Benefits |
|
|
- Discharge of condensate without
subcooling
- Automatic air venting when system
is cold
- Operation in systems with variable
pressures
- Easy in-line maintenance and
repair
- Long service time
- Conversion of flow direction
possible
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Vaposcop
VK16 (Sightglass) |
|
Model
# |
Sightless for
checking heat exchangers and steam traps (installation upstream
of the traps). Visual supervision of flow conditions in condensate
lines. The Vapsocope can be used in horizontal and vertical pipe
work without any modifications. Installation upstream of the
steam trap. The application is limited to fluids with pH value
10. VK16 comes standard with mica disc. |
|
|
Features
and Benefits |
|
|
- Visual supervision of slow
conditions in condensate lines
- Standard with mica disc.
- Body made of C22.8 / ASSTM
A105
- Size DN 15 - 50
|
|
|
|
|
|
|
|
|
|
|
|
This
site is © Copyright Caribe Gasket 2009, All Rights Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|